REF 70N0005000 / 70N0010000 / 70N0020000 / 70N0030000 / 70N0050000 / 70N0080000 / 70N0100000 / 70N0125000 / 70N0160000 / 70N0200000 / 70N0250000 / 70N0315000 / 70N0400000 / 70N0500000 / 70N0630000 / 70N0800000 / 70N1000000 / 70N1250000 / 70N1600000 / 70N2000000 / 70C0005000 / 70C0010000 / 70C0020000 / 70C0030000 / 70C0050000 / 70C0080000 / 70C0100000 / 70C0125000 / 70C0160000 / 70C0200000 / 70C0250000 / 70C0315000 / 70C0400000 / 70C0500000 / 70C0630000 / 70C0800000 / 70C1000000 / 70C1250000 / 70C1600000 / 70C2000000
VOLTAGES | POWER | REFERENCE | ||||
---|---|---|---|---|---|---|
IP00 |
IP23 |
|||||
TRT30 REVERSIBLE |
230-400V | 0,5kVA | 70N0005000 | 70C0005000 | ||
1kVA | 70N0010000 | 70C0010000 | ||||
2kVA | 70N0020000 | 70C0020000 | ||||
3kVA | 70N0030000 | 70C0030000 | ||||
5kVA | 70N0050000 | 70C0050000 | ||||
8kVA | 70N0080000 | 70C0080000 | ||||
10kVA | 70N0100000 | 70C0100000 | ||||
12,5kVA | 70N0125000 | 70C0125000 | ||||
16kVA | 70N0160000 | 70C0160000 | ||||
20kVA | 70N0200000 | 70C0200000 | ||||
25kVA | 70N0250000 | 70C0250000 | ||||
31,5kVA | 70N0315000 | 70C0315000 | ||||
40kVA | 70N0400000 | 70C0400000 | ||||
50kVA | 70N0500000 | 70C0500000 | ||||
63kVA | 70N0630000 | 70C0630000 | ||||
80kVA | 70N0800000 | 70C0800000 | ||||
100kVA | 70N1000000 | 70C1000000 | ||||
125kVA | 70N1250000 | 70C1250000 | ||||
160kVA | 70N1600000 | 70C1600000 | ||||
200kVA | 70N2000000 | 70C2000000 | ||||
OTHER CHARACTERISTICS ON REQUEST SUBJECT TO AVAILABILITY AND POSSIBILITY |
Use | Reversible autotransformer. Indoor use. Dry type. For stationary installation. Continuous operation (ED100%). |
Rated voltages | 230-400V |
Rated power range | 0,5kVA to 200kVA 0,5kVA to 3kVA: IEC/EN61558-13 5kVA to 200kVA: IEC60076-11 |
Vector group | YN0 connection (star with accessible neutral) |
Protection against electric shock | Class I |
Thermal class | ≤ 25kVA: B (130°C) ≥ 31,5kVA: H (180°C) |
Rated ambient temperature | 40ºC |
Protection index | IP00 | IP23 |
Frequency | 50/60Hz |
Dielectric strength | > 3kV |
Ambient temperature of service * | -20°C ... 70°C |
Storage temperature | -40°C ... 85°C |
Cooling | Natural air cooling If the transformer is placed into a cabinet, it must have adequate ventilation. |
* For ambient temperatures higher than 40ºC it is necessary to apply a derating. Non short circuit proof. The user must install the appropriate protection devices (see data sheet). |
IEC/EN 61558-1 Transformers, general specifications
IEC/EN 61558-2-13 Autotransformers for general use
IEC60076-11 Dry type power transformers
RoHS Compliant
Copper windings Class F (155°C) or H (180°C) |
Reinforced insulation |
Flexible insulating materials Class B (130°C) or H (180°C) |
Impregnation Class H (180°C) |
Connection with terminal blocks protected against accidental contacts up to 63 kVA and screws for terminals for powers from 80kVA up to 200kVA. |
With eyebolts for rated power from 20kVA. |
Metallic case with index protection IP23 painted with epoxy in RAL7032 colour |
POWER | DIMENSIONS | WEIGHT | |||||
kVA | A | B | C | D | E | F | kg |
0,5 | 180 | 85 | 210 | 140 | 55 | 6 | 5,5 |
1 | 180 | 85 | 210 | 140 | 55 | 6 | 6,5 |
2 | 180 | 95 | 210 | 140 | 65 | 6 | 9,1 |
3 | 240 | 110 | 260 | 200 | 75 | 6 | 16 |
5 | 240 | 120 | 260 | 200 | 85 | 6 | 18 |
8 | 240 | 145 | 261 | 200 | 110 | 6 | 27 |
10 | 300 | 135 | 311 | 200 | 95 | 6 | 31 |
12,5 | 300 | 145 | 311 | 200 | 105 | 6 | 40 |
16 | 300 | 165 | 316 | 200 | 125 | 6 | 44 |
20 | 360 | 170 | 366 | 300 | 115 | 8 | 56 |
25 | 360 | 180 | 366 | 300 | 125 | 8 | 68 |
31,5 | 420 | 200 | 425 | 300 | 140 | 8 | 86 |
40 | 420 | 210 | 425 | 300 | 150 | 8 | 100 |
50 | 480 | 225 | 500 | 400 | 155 | 10 | 107 |
63 | 480 | 240 | 500 | 400 | 175 | 10 | 135 |
80 | 480 | 280 | 510 | 400 | 195 | 10 | 160 |
100 | 480 | 300 | 510 | 400 | 215 | 10 | 180 |
125 | 600 | 320 | 600 | 500 | 180 | 16 | 240 |
160 | 600 | 340 | 600 | 500 | 200 | 16 | 270 |
200 | 600 | 350 | 530 | 500 | 220 | 16 | 325 |
These dimensions belongs to autotransformers with rated voltage of 230-400V. For another voltages the dimensions can be very different. |
POWER | DIMENSIONS | WEIGHT | |||||
kVA | A | B | C 1 | D | E | F | kg |
0,5 | 235 | 240 | 285 | 140 | 215 | 12 | 9,0 |
1 | 235 | 240 | 285 | 140 | 215 | 12 | 9,5 |
2 | 235 | 240 | 285 | 140 | 215 | 12 | 12 |
3 | 285 | 290 | 335 | 200 | 265 | 12 | 20 |
5 | 285 | 290 | 335 | 200 | 265 | 12 | 22,5 |
8 | 285 | 290 | 335 | 200 | 265 | 12 | 31 |
10 | 375 | 300 | 435 | 200 | 270 | 12 | 38 |
12,5 | 375 | 300 | 435 | 200 | 270 | 12 | 47 |
16 | 375 | 300 | 435 | 200 | 270 | 12 | 51 |
20 | 450 | 400 | 480 | 300 | 370 | 12 | 66 |
25 | 450 | 400 | 480 | 300 | 370 | 12 | 78 |
31,5 | 510 | 400 | 540 | 300 | 370 | 12 | 97 |
40 | 510 | 400 | 540 | 300 | 370 | 12 | 111 |
50 | 540 | 500 | 610 | 400 | 470 | 12 | 126 |
63 | 540 | 500 | 610 | 400 | 470 | 12 | 156 |
80 | 540 | 500 | 610 | 400 | 470 | 12 | 180 |
100 | 540 | 500 | 610 | 400 | 470 | 12 | 197 |
160 | 880 | 530 | 830 | 500 | 500 | 12 | 300 |
200 | 880 | 730 | 830 | 500 | 500 | 12 | 365 |
These dimensions belongs to autotransformers with rated voltage of 230-400V. For another voltages the dimensions can be very different. 1 Eyebolts ≥ 20kVA +45mm |