Range

PRI VOLTAGE SEC VOLTAGE POWER REFERENCE
ta 40°C ta 25°C 12-24V
24-48V
115-230V
TR28 5.2
CONTROL
SAFETY
ISOLATING
0-230-400-460V ±15V 12-24V
24-48V
115-230V
25VA 40VA 680025010 680025011 680025012
40VA 63VA 680040010 680040011 680040012
63VA 100VA 680063010 680063011 680063012
100VA 130VA 680100010 680100011 680100012
160VA 200VA 680100010 680100011 680100012
200VA 250VA 680200010 680200011 680200012
320VA 400VA 680250010 680250011 680250012
250VA 320VA 680320010 680320011 680320012
TR28 5.2
CONTROL
SAFETY
ISOLATING
0-230-400-460V ±15V 12-24V
24-48V
115-230V
400VA 500VA 680400010 680400011 680400012
500VA 630VA 680500010 680500011 680500012
TR28 5.2
CONTROL
SAFETY
ISOLATING
0-230-400-460V ±15V 12-24V
24-48V
115-230V
630VA 800VA 680630010 680630011 680630012
800VA 1000VA 680800010 680800011 680800012
1000VA 1250VA 681000010 681000011 681000012

Technical data

Use SEC 12-24V
Control and safety transformer


SEC 24-48V | 115-230V
Control and isolating transformer
Rated primary voltage 0-230-400-460V ±15V
Rated secondary voltage 12-24V
24-48V
115-230V
Rated power range 25VA ... 1000VA
Protection against electric shock Class I
Thermal class B (130ºC)
Rated ambient temperature 40ºC
Protection index IP20
Frequency 50/60Hz
Dielectric strength between primary
and secondary
≥4,5kV
Dielectric strength between windings
and metallic parts
≥2,5kV
Ambient temperature of service * -20°C ... 70°C
Storage temperature -40°C ... 85°C
* For ambient temperatures higher than 40ºC it is necessary to apply a derating.

Standards

IEC/EN 61558-1 Transformers, general specifications
IEC/EN 61558-2-2 Control transformers
IEC/EN 61558-2-4 Isolating transformers
IEC/EN 61558-2-6 Safety transformers
RoHS Compliant

Constructive characteristics

Two identical secondary winding intended for serial or parallel connection (jumpers supplied with the transformer)
Windings in F(155°C) or H(180°C) thermal class
Flexible insulation Class B(130°C)
Impregnation Class B(130ºC)
Great capacity clamp type terminal blocks:

up to 320VA > 10mm2 (max. torque 2Nm)
up to 1000VA > 25mm2 (max. torque 2,5Nm)

Screw earth connection (standard IEC/EN61558 prescribes in the clause 24 that it should not be possible to loosen the protection wire without the aid of a tool)
TIG welded magnetic core prevent vibration and allows small air gap to reduce the magnetization current
Fixing on symmetric rail in rated power up to 320VA

Dimensions

POWER DIMENSIONS WEIGHT
VA A B C D E F G kg
25 84 113 96 101 66 5 7,5 1,17
40 84 113 105 101 66 5 7,5 1,48
63 84 113 112 101 66 5 7,5 1,83
100 84 113 116 101 66 5 7,5 2,00
160 84 113 131 101 66 5 7,5 2,65
200 108 135 133 120 82 6,5 9,5 4,20
250 108 135 138 120 82 6,5 9,5 4,45
320 108 135 148 120 82 6,5 9,5 5,00
400 120 152 141 135 94 7 9,5 5,86
500 120 152 156 135 94 7 9,5 7,08
630 150 177 140 160 115 7 2 8,68
800 150 177 160 160 115 7 2 11,5
1000 150 177 182,6 160 115 7 2 14,4

Secondary connection

TRANSFORMER 0-230-400-460//24-48V 100VA
REF 610100011

Serial connection

Parallel connection

With middle tap

Other versions

POWER 25VA...3000VA
PRI VOLTAGE 0-230-400V
SEC VOLTAGE 12-24V
24-48V
115-230V