Range

PRI VOLTAGE SEC VOLTAGE POWER
TR23
CUSTOMER DESIGN

ON REQUEST ON REQUEST 10-12-16-20VA
25-30VA
40VA
50VA
63VA
100VA
160VA
200VA
250VA
320VA
400VA
500VA
630VA
800VA
1000VA

Technical data

Rated primary voltage ON REQUEST
10VA...30VA > max 440V
40VA...1000VA > max 750V
Rated secondary voltage ON REQUEST
10VA...30VA > max 440V
40VA...1000VA > max 750V
Rated power range 10VA ... 1000VA
Protection against electric shock Class I
Thermal class B (130ºC)
Rated ambient temperature 40ºC
Protection index IP00
Frequency 50/60Hz
Dielectric strength between primary
and secondary
≥4,5kV
Dielectric strength between windings
and metallic parts
≥2,5kV
Ambient temperature of service * -25°C ... 70°C
Storage temperature -40°C ... 85°C
* For ambient temperatures higher than 40ºC it is necessary to apply a derating.

Standards

IEC/EN 61558-1 Transformers, general specifications
IEC/EN 61558-2-1 General use transformers
IEC/EN 61558-2-2 Control transformers
IEC/EN 61558-2-4 Isolating transformers
IEC/EN 61558-2-6 Safety transformers
RoHS Compliant

Constructive characteristics

Windings in F(155°C) or H(180°C) thermal class
Flexible insulation Class F (130°C)
Impregnation Class F (155°C)
Connections with accidental contact protected terminal blocks
Screw earth connection (standard IEC/EN61558 prescribes in the clause 24 that it should not be possible to loosen the protection wire without the aid of a tool)
TIG welded magnetic core prevent vibration and allows small air gap to reduce the magnetization current

Dimensions

TABLE 1

FOR TRANSFORMERS WITH THE FOLLOWING CHARACTERISTICS:

· Only one primary voltage up to 400V
· Only one secondary voltage between 12 and 230V
· WITHOUT electrostatic screen

For transfomers with other characteristics APPLY TABLE 2

POWER DIMENSIONS WEIGHT
VA A B 1 C 2 D E F kg
10-12-16-20-25 60 71 77 44 39 3,6 0,51
30-40 60 76 77 44 49 3,6 0,74
50 75 77 88 56 54 4,8 1,00
63 75 82 88 56 54 4,8 1,10
100 84 80 95 64 52 4,8 1,35
160 84 94 95 64 67 4,8 1,96
200 96 96 106 84 77 5,7 2,68
250 96 110 106 84 91 5,7 3,35
320 SEE TABLE 2
400
500
630
800
1000
1 Terminal block with fuse: +8,5mm
Terminal block with current > 32A: +16mm


2 Terminal block with fuse: +5mm
Terminal block with current > 32A: +8,5mm

TABLE 2

POWER DIMENSIONS WEIGHT
VA A B 1 C 2 D E F kg
10-12-16-20 60 71 77 44 39 3,6 0,51
25-30 60 80 77 44 49 3,6 0,74
40 75 77 88 56 47 4,8 1,00
50 75 82 88 56 54 4,8 1,10
63 84 80 95 64 52 4,8 1,35
100 84 94 95 64 67 4,8 1,96
160 96 96 106 84 77 5,7 2,68
200 96 110 106 84 91 5,7 3,35
250 108 99 115 80,5 73 5,7 3,64
320 108 111 115 80,5 87 5,7 4,40
400 120 106 124 90 87 5,7 4,90
500 120 126 124 90 107 5,7 6,70
630 150 114 146 122 92 6,8 7,50
800 150 133 146 122 108 6,8 9,80
1000 150 156 146 122 135 6,8 13,2
1 Terminal block with fuse: +8,5mm
Terminal block with current > 32A: +16mm


2 Terminal block with fuse: +5mm
Terminal block with current > 32A: +8,5mm