HORUS® photovoltaic fuse holders and bases
HORUS® cylindrical fuse holders and NH fuse bases are designed for photovoltaic string circuits, DC distribution and 800 V AC inverter outputs.
Our HORUS® fuse holders and bases provide the mounting and electrical connection for photovoltaic fuse links. The range includes PMX PV cylindrical fuse holders, the PMLe holder for 85 mm fuse links, NH bases for 1000 V DC, NH XL bases for 1500 V DC and NH bases for 800 V AC. Select the holder or base to match the fuse size, circuit voltage and operating current. Then check the fuse power loss against the power acceptance of the holder at the intended load and ambient temperature. Explore the complete HORUS photovoltaic range for matching fuse links.


PMX PV holders cover 10×38, 14×51 and 22×65 mm fuse links. The PMLe holder accepts 10×85 and 10/14×85 mm fuse links. Depending on the model, DC ratings extend from 1000 to 1500 V.
| Main function |
|---|
| Mounting and connection of cylindrical fuse links |
| Typical applications |
|---|
| PV string circuits and combiner boxes |
| Range |
|---|
| PMX PV 10×38 mm PMX PV 14×51 mm PMX PV 22×65 mm PMLe 10×85 and 10/14×85 mm |


The 1000 V DC range uses NH1, NH2 and NH3 sizes. For 1500 V DC, choose the extended NH1 XL, NH2 XL and NH3 L formats. Each base accepts the corresponding knife-blade fuse link.
| Main function |
|---|
| Mounting and connection of NH gPV fuse links |
| Typical applications |
|---|
| PV sub-arrays, arrays and inverter DC inputs |
| Range |
|---|
| NH ST bases at 1000 V DC NH XL bases at 1500 V DC |
NH00, NH1 and NH3 bases cover inverter output circuits at 800 V AC. Single-pole and three-pole versions are available, with mounting and terminal options depending on the size and reference.
| Main function |
|---|
| Mounting and connection of NH fuse links |
| Typical applications |
|---|
| 800 V AC inverter output circuits |
| Range |
|---|
| NH00 ST at 800 V AC NH1 ST at 800 V AC NH3 ST at 800 V AC |
Which fuse holder or base fits your installation?
Compare voltage, holder rated current, pole configuration and power acceptance. The current shown is the rating of the holder or base, not the available current range of its fuse links. Select a product name for dimensions, accessories and order references.
Comparison table
Cylindrical photovoltaic fuse holders
Scroll the table horizontally to compare all sizes.
![]() |
![]() |
![]() |
![]() |
|
| Feature | PMX PV 10×38 mm | PMX PV 14×51 mm | PMX PV 22×65 mm | PMLe 10/14×85 mm |
|---|---|---|---|---|
| Typical Application | PV strings | PV strings | 1500 V DC circuits | 1500 V DC circuits |
| Compatible Fuse Size | 10×38 mm | 14×51 mm | 22×65 mm | 10×85 mm 10/14×85 mm |
| Rated DC Voltage | 1000 V DC | 1100 V DC | 1500 V DC | 1500 V DC |
| Holder Rated Current | 32 A | 50 A | 100 A | 32 A |
| Power Acceptance1 | 4 W | 6 W | 12 W | 7.5 W |
| Poles | 1P / 2P | 1P / 2P | 1P | 1P |
| IP Protection2 | IP20 | IP20 | IP20 | IP20 |
1Power acceptance
Power acceptance applies to the holder or base. Check the selected fuse’s power loss at the intended load and the permitted operating conditions of the complete assembly.
2Protection and installation
For IP20 protection, use the specified cable-entry accessory where cable diameter is ≤4.5 mm for PMX PV 10×38 and PMLe, or ≤6 mm for PMX PV 14×51 and 22×65.
Comparison table
NH photovoltaic fuse bases for DC circuits
Scroll the table horizontally to compare all sizes.
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
|
| Feature | NH1 ST 1000 V DC | NH2 ST 1000 V DC | NH3 ST 1000 V DC | NH1 XL 1500 V DC | NH2 XL 1500 V DC | NH3 L 1500 V DC |
|---|---|---|---|---|---|---|
| Typical Application | PV DC distribution | PV DC distribution | PV DC distribution | 1500 V DC distribution | 1500 V DC distribution | 1500 V DC distribution |
| Rated DC Voltage | 1000 V DC | 1000 V DC | 1000 V DC | 1500 V DC | 1500 V DC | 1500 V DC |
| Base Rated Current | 250 A | 400 A | 500 A | 200 A | 315 A | 500 A |
| Power Acceptance1 | 32 W | 45 W | 60 W | 45 W | 75 W | 85 W |
| Poles | 1P | 1P | 1P | 1P | 1P | 1P |
| Mounting | DIN rail / screw | DIN rail / screw | DIN rail / screw | Screw | Screw | Screw |
| IP Protection2 | IP00 / IP20 on terminals |
IP00 / IP20 on terminals |
IP00 / IP20 on terminals |
IP00 / IP20 on terminals |
IP00 / IP20 on terminals |
IP00 / IP20 on terminals |
1Power acceptance
Power acceptance applies to the holder or base. Check the selected fuse’s power loss at the intended load and the permitted operating conditions of the complete assembly.
2Protection and installation
IP20 applies to the terminals with the appropriate protection accessories. The unprotected base is IP00.
Comparison table
NH fuse bases for 800 V AC inverter outputs
Scroll the table horizontally to compare all sizes.
![]() |
![]() |
![]() |
|
| Feature | NH00 ST 800 V AC | NH1 ST 800 V AC | NH3 ST 800 V AC |
|---|---|---|---|
| Typical Application | Inverter AC outputs | Inverter AC outputs | Inverter AC outputs |
| Rated AC Voltage | 800 V AC | 800 V AC | 800 V AC |
| Base Rated Current | 160 A | 250 A | 630 A |
| Power Acceptance1 | 12 W (IEC) 25 W (maximum) |
25 W | 60 W |
| Poles | 1P / 3P | 1P / 3P | 1P / 3P |
| Mounting | Screw or DIN rail / screw | DIN rail / screw | DIN rail / screw |
| IP Protection2 | IP00 / IP20 | IP00 / IP20 | IP00 / IP20 |
1Power acceptance
Power acceptance applies to the holder or base. Check the selected fuse’s power loss at the intended load and the permitted operating conditions of the complete assembly. For NH00, 12 W is specified according to IEC 60269-2; 25 W is the stated maximum.
2Protection and installation
IP20 protection depends on the selected version and protection accessories. For NH00, fixing options also depend on the order reference.
Applications of HORUS fuse holders and bases
The holder or base must suit the electrical duty and the physical layout of the circuit. The cylindrical, standard NH and extended NH ranges address different positions in a photovoltaic installation.
01
PV string circuits
PMX PV 10×38 mm holders provide a compact connection for cylindrical gPV fuse links at up to 1000 V DC. Choose the pole configuration and indication option required by the circuit.
02
Higher-voltage strings
The PMX PV 14×51 mm holder is rated at 1100 V DC. For 1500 V DC circuits, the PMX PV 22×65 mm and PMLe holders accept their respective cylindrical fuse formats.
03
PV sub-arrays
At 1000 V DC, NH ST bases offer NH1, NH2 and NH3 sizes. Their single-pole construction and DIN rail or screw fixing allow integration into distribution assemblies.
04
Inverter DC inputs
NH XL bases support the extended knife-blade formats used at 1500 V DC. NH1 XL, NH2 XL and NH3 L bases have rated currents of 200, 315 and 500 A respectively.
05
Inverter AC outputs
For an 800 V AC output circuit, select an NH00, NH1 or NH3 base with a suitable fuse link. The range includes single-pole and three-pole configurations.
06
Equipment integration
For designs using separate contacts, our clips for 10 mm cylindrical fuse links are available for screw or PCB mounting. Their voltage suitability depends on the insulation distances in the finished assembly.
Selecting a HORUS fuse holder or base
Check the complete fuse and holder combination before choosing an order reference. Electrical ratings, heat dissipation and the installation accessories all affect the final configuration.
01
Match the fuse format
Use the exact cylindrical or NH size specified for the holder. An NH XL base for 1500 V DC is a different format from a standard NH base for 1000 V DC.
02
Check the circuit voltage
Select the appropriate AC or DC rating. The 800 V AC rating of an inverter-output base does not establish its suitability for a photovoltaic DC circuit.
03
Allow for fuse heating
Compare the fuse power loss at the intended current with the holder’s power acceptance. Include the effects of ambient temperature and installation conditions when selecting the combination.
04
Choose the pole configuration
PMX PV 10×38 and 14×51 mm holders offer one-pole and two-pole versions. The NH DC bases are single-pole; the NH AC ranges also include three-pole versions.
05
Specify protection accessories
Terminal covers, separating plates and cable-entry protection depend on the model. Select the accessories required to achieve the stated level of protection in the assembled installation.
06
Plan indication and handling
A compatible NH top indicator can actuate our indicator microswitch. Use the appropriate standard NH handle or NH XL handle for the fuse format and voltage. NH bases must not be operated under load.
Need to know
Is the holder rated current the same as the fuse rating?
No. The holder current rating describes the holder itself. For example, the PMX PV 22×65 mm holder is rated at 100 A, but this does not mean that any 100 A fuse can be fitted. Check fuse size, voltage, available fuse ratings and power loss for the complete combination.
Which holder accepts 10×85 and 10/14×85 mm fuse links?
The PMLe holder accepts both formats and is rated at 32 A and 1500 V DC. Its power acceptance is 7.5 W. Check the voltage and power loss of the selected fuse link as well as its dimensions.
What does power acceptance mean?
It is the fuse power loss that the holder or base can accommodate under the specified conditions. It differs from the losses generated by the holder’s own connections. Use the product data and the intended operating conditions to check the complete assembly.
Can a bolted NH fuse link be fitted in an NH base?
Our NH bases accept the corresponding knife-blade fuse links. Bolted versions connect directly to the busbar and require the mounting arrangement specified for that fuse.
Are NH bases suitable for switching under load?
No. NH fuse bases must not be operated under load. Use the specified handling equipment and follow the installation and safety instructions for the product.
How is IP20 protection obtained?
The required arrangement depends on the product. Cylindrical holders may need cable-entry protection for smaller cable diameters. NH DC bases provide IP20 protection on the terminals with the appropriate accessories; this does not make the entire assembly IP20.
Which bases are available for 800 V AC?
The 800 V AC NH range includes NH00 at 160 A, NH1 at 250 A and NH3 at 630 A. Single-pole and three-pole versions are available. Select the reference for the required fixing and terminal arrangement.
How can an NH fuse be monitored remotely?
Use the indicator microswitch with a compatible NH fuse link equipped with a top indicator. Check the fuse indicator and accessory compatibility before selecting the assembly.
Where can I find dimensions and order references?
Open the relevant product from a comparison-table heading. Its product page includes the available references, technical characteristics, dimensional drawings and accessories.