REF 660130000 / 660350000 / 660700000 / 660130001 / 660350001 / 660700001
PRI VOLTAGE | SEC VOLTAGE | POWER | REFERENCE | FOR SPOTLIGHT | DISTANCES | ||
---|---|---|---|---|---|---|---|
TRANSFOMER SPOTLIGHT | |||||||
TR26 IP20 SAFETY FOR SWIMMING POOL SPOTLIGHTS |
230V | 12V | 130VA | 660130000 | 1x12V 100W | 10-18-25m | |
350VA | 660350000 | 1x12V 300W | 10-25-40m | ||||
700VA | 660700000 | 2x12V 300W | 10-25-40m | ||||
TR26 IP00 SAFETY FOR SWIMMING POOL SPOTLIGHTS |
230V | 12V | 130VA | 660130001 | 1x12V 100W | 10-18-25m | |
350VA | 660350001 | 1x12V 300W | 10-25-40m | ||||
700VA | 660700001 | 2x12V 300W | 10-25-40m | ||||
Rated primary voltage | 230V |
Rated secondary voltage | 12V |
Rated power range | 130VA | 350VA | 700VA |
Protection against electric shock | Class I |
Thermal class | B (130ºC) F (155°C) |
Rated ambient temperature | 40ºC |
Protection index | IP00 | IP20 |
Frequency | 50/60Hz |
Dielectric strength between primary and secondary |
≥4,5kV |
Dielectric strength between windings and metallic parts |
≥2,5kV |
Ambient temperature of service * | -25°C ... 70°C |
Storage temperature | -40°C ... 85°C |
* For ambient temperatures higher than 40ºC it is necessary to apply a derating. |
IEC/EN 61558-1 Transformers, general specifications
IEC/EN 61558-2-6 Safety transformers
Electrostatic screen between primary and secondary |
Windings in F(155°C) or H(180°C) thermal class |
Flexible insulation Class B(130ºC) or F(155°C) |
Impregnation with varnish Class F(155°C) |
Casing and mount base in polyamide self extinguishable |
TIG welded magnetic core prevent vibration and allows small air gap to reduce the magnetization current |
We use cookies from third party services for a better user experience. If you continue browsing you are giving your consent for the acceptance of our Cookies Policy.