REF 610040000 / 610063000 / 610100000 / 610160000 / 610200000 / 610250000 / 610320000 / 610400000 / 610500000 / 610630000 / 610800000 / 611000000 / 610040001 / 610063001 / 610100001 / 610160001 / 610200001 / 610250001 / 610320001 / 610400001 / 610500001 / 610630001 / 610800001 / 611000001 / 610040002 / 610063002 / 610100002 / 610160002 / 610200002 / 610250002 / 610320002 / 610400002 / 610500002 / 610630002 / 610800002 / 611000002
PRI VOLTAGE | SEC VOLTAGE | POWER | REFERENCE | ||||
---|---|---|---|---|---|---|---|
12-24V |
24-48V |
115-230V |
|||||
TR21 CONTROL |
0-230-400V | 12-24V 24-48V 115-230V |
40VA | 610040000 | 610040001 | 610040002 | |
63VA | 610063000 | 610063001 | 610063002 | ||||
100VA | 610100000 | 610100001 | 610100002 | ||||
160VA | 610160000 | 610160001 | 610160002 | ||||
200VA | 610200000 | 610200001 | 610200002 | ||||
250VA | 610250000 | 610250001 | 610250002 | ||||
320VA | 610320000 | 610320001 | 610320002 | ||||
400VA | 610400000 | 610400001 | 610400002 | ||||
500VA | 610500000 | 610500001 | 610500002 | ||||
630VA | 610630000 | 610630001 | 610630002 | ||||
800VA | 610800000 | 610800001 | 610800002 | ||||
1000VA | 611000000 | 611000001 | 611000002 |
Use | SEC 12-24V Control and safety transformer SEC 24-48V | 115-230V Control and isolating transformer |
Rated primary voltage | 0-230-400V |
Rated secondary voltage | 12-24V 24-48V 115-230V |
Rated power range | 40VA ... 1000VA |
Protection against electric shock | Class I |
Thermal class | B (130ºC) |
Rated ambient temperature | 40ºC |
Protection index | IP00 |
Frequency | 50/60Hz |
Dielectric strength between primary and secondary |
≥4,5kV |
Dielectric strength between windings and metallic parts |
≥2,5kV |
Ambient temperature of service * | -20°C ... 70°C |
Storage temperature | -40°C ... 85°C |
* For ambient temperatures higher than 40ºC it is necessary to apply a derating. |
IEC/EN 61558-1 Transformers, general specifications
IEC/EN 61558-2-2 Control transformers
IEC/EN 61558-2-4 Isolating transformers
IEC/EN 61558-2-6 Safety transformers
RoHS Compliant
Two identical secondary winding intended for serial or parallel connection (jumpers supplied with the transformer) |
Reinforced insulation |
Windings in F(155°C) or H(180°C) thermal class |
Flexible insulation Class B (130°C) |
Impregnation Class F (155°C) |
Connections with accidental contact protected terminal blocks |
Screw earth connection (standard IEC/EN61558 prescribes in the clause 24 that it should not be possible to loosen the protection wire without the aid of a tool) |
TIG welded magnetic core prevent vibration and allows small air gap to reduce the magnetization current |
POWER | DIMENSIONS | WEIGHT | |||||
VA | A | B | C | D | E | F | kg |
40 | 75 | 83 | 88 | 56 | 47 | 4,8 | 1,00 |
63 | 84 | 86 | 95 | 64 | 67 | 4,8 | 1,40 |
100 | 84 | 100 | 95 | 64 | 67 | 4,8 | 1,96 |
160 | 96 | 102 | 106 | 84 | 77 | 5,7 | 2,80 |
200 | 96 | 116 | 106 | 84 | 91 | 5,7 | 3,40 |
250 | 108 | 105 | 115 | 80,5 | 73 | 5,7 | 3,64 |
320 | 108 | 117 | 115 | 80,5 | 87 | 5,7 | 4,54 |
400 | 120 | 110 1 | 124 2 | 90 | 87 | 5,7 | 5,20 |
500 | 120 | 126 1 | 124 2 | 90 | 107 | 5,7 | 6,85 |
630 | 150 | 114 1 | 146 2 | 122 | 92 | 6,8 | 7,50 |
800 | 150 | 133 3 | 146 4 | 122 | 108 | 6,8 | 10,2 |
1000 | 150 | 156 3 | 146 4 | 122 | 135 | 6,8 | 13,6 |
1 SEC 12-24V > +20mm 2 SEC 12-24V > +7,5mm 3 SEC 12-24V - SEC 24-48V > +20mm 4 SEC 12-24V - SEC 24-48V > +7,5mm |
TRANSFORMER 0-230-400//24-48V 100VA
REF 610100001
We use cookies from third party services for a better user experience. If you continue browsing you are giving your consent for the acceptance of our Cookies Policy.