REF 485101 / 485102 / 485120 / 485103 / 485104 / 485105 / 485121 / 485106 / 485107 / 485108 / 485109 / 485110 / 485111 / 485112 / 485113 / 485114 / 485116 / 10×38 / gG / aM / aR / gR / rapidplus
SIZE | Un | In | POLES | MODULES | REFERENCE | |
---|---|---|---|---|---|---|
WITHOUT INDICATOR![]() |
WITH INDICATOR![]() |
|||||
10x38 | 690V AC 750V DC |
32A | 1P | 1 | 485101 ![]() ![]() |
485108 ![]() ![]() |
N | 1 | 485102 ![]() ![]() |
- | |||
1P + N | 1 | 485120 | - | |||
1P + N | 2 | 485103 ![]() ![]() |
485109 ![]() ![]() |
|||
2P | 2 | 485104 ![]() ![]() |
485110 ![]() ![]() |
|||
3P | 3 | 485105 ![]() ![]() |
485111 ![]() ![]() |
|||
3P + N | 3 | 485121 | - | |||
3P + N | 4 | 485106 ![]() ![]() |
485112 ![]() ![]() |
|||
4P | 4 | 485107 ![]() ![]() |
485113 ![]() ![]() |
|||
24V DC | 32A | 1P | 1 | - | 485114 ![]() ![]() |
|
2P | 2 | - | 485116 ![]() ![]() |
Rated current | 32A |
Rated voltage | 690V AC | 750V DC |
Rated power dissipation | 3W |
Maximum power dissipation | 4W |
Power dissipation per pole (with neutral link) |
80% In 100% In |
Power dissipation (1P+N | 1 module) |
80% In 100% In |
Power dissipation (3P+N | 3 modules) |
80% In 100% In |
Utilization category (EN 60947-3) | 500V AC 690V AC 750V DC |
Pollution degree | 3 |
Protection index * | IP20 |
Rated impulse withstand voltage | 6kV U imp |
Ambient temperature of service | -20°C ... 70°C |
Storage temperature | -40°C ... 80°C |
* For wires of section ≤ 6mm2 is necessary to use the accessory indicated to guarantee IP20 in clamps zone. |
IEC/EN 60269-1
IEC/EN 60269-2
UL4248-1 Fuse holders
UL486E Wiring terminals
CSA C22.2 Nº 4248-1 Fuse holder assemblies
CSA 22.2 Nº 65 Wire connectors
Standard system by DF Electric: 3 clips and 1 pin for each union between poles.
REFERENCE | DESCRIPTION |
480005 | Pins for multipole assembly |
485050 | Handle ties for multipole assembly |
Open the label holder part with the fuse holder closed, put on the label and close it. Label measures: 11x9mm.
The accessory mut be positioned in the wire entries, if it’s neccesary to achieve the IP20 degree of protection with thin wires.
REFERENCE | DESCRIPTION |
485052 | Special IP20 protection accessory |
The accessory increases the distance between phases in multipolar asemblies.
REFERENCE | DESCRIPTION |
485053 | Phase Separator accessory |
Protection accesory to avoid the screws manipulation and improve the protection degree.
REFERENCE | DESCRIPTION |
485656 | Screws protection accessory |
First mount the accessory with screws, then mount the fuse holder
(there are available different accessories depending the number of the fuse holder)
Systems to avoid the operation and connection when the fuse holder is open or closed.
REFERENCE | DESCRIPTION |
485051 | Lock accessory |
![]() |
![]() |
![]() |
![]() |
|
10x38 Cylindrical gG fuse link | 10x38 Cylindrical aM fuse link | 10x38 Cylindrical gR Semiconductor fuse link | 10x38 Cylindrical aR Semiconductor fuse link | |
U | 500V 400V |
500V 400V |
690V | 690V |
In | 0,5A...25A (500V) 32A (400V) |
0,16A...16A (500V) 20A | 25A (400V) |
1A...32A | 1A...32A |
Breaking capacity | 120kA | 120kA | 200kA 30kA @440V DC |
200kA 30kA @700V DC |